Windows Sealing Service

“Sealing a window” covers three different things that fail in three different ways: the gasket the sash closes onto, the sealant between frame and wall, and the drainage that lets trapped water escape. Fixing the wrong one is why draughts and leaks keep coming back.

  • Manufacturing since 2007
  • 5,000+ windows installed
  • 219 corporate partners
Close-up of a technician drilling a fixing into the side of a white window frame

Get a quote in one working day

Three fields. No obligation.

Or call +91 80979 88888

Why windows sealing service

The leak is diagnosed first

Where the water enters tells you which seal has failed. We find that before applying anything.

Drainage kept open, not sealed shut

The most common well-meant mistake is sealing over the weep holes, which makes water ingress worse.

Gaskets replaced, not packed

A hardened gasket is replaced with the correct profile rather than padded out with foam tape.

Noise and dust drop with the draughts

The same air path carries all three, so sealing properly fixes more than the cold spot you noticed.

Three seals, three failure modes

The gasket

The rubber or EPDM profile the sash compresses against when it closes. This is the seal that does the daily work — it stops air, sound and driven rain when the window is shut.

It fails by hardening. Years of heat and UV take the elasticity out of it, and once it no longer springs back, the sash closes onto a rigid strip instead of a compressible one. Symptoms: draughts, rattling in wind, road noise getting worse, and dust on the sill.

Fix: replace with the correct profile for that system. Packing it out with foam tape is a common shortcut that closes the gap and jams the sash.

The perimeter seal

The line of sealant between the outside of the frame and the wall. It is what stops water getting into the gap around the window.

It fails by shrinking, cracking or lifting, usually at the corners first, and usually because it was applied to a dusty or damp surface. Symptoms: damp patches at the jambs or above the window, particularly after wind-driven rain.

Fix: cut out the failed sealant entirely, prepare the surface, and reapply. Smearing new sealant over old is the single most common reason a leak returns.

The drainage path

Not a seal at all, but it is where most “sealing” jobs go wrong. Every properly made window expects some water to reach the rebate and drains it back out through weep holes at the sill.

It fails by silting up with dust. Symptoms: water pooling on the sill inside, or seeping from the bottom of the frame, typically in the first heavy rain of the season.

Fix: clear and flow-test the slots. Never seal them.

Diagnosing it yourself

Where the water appears tells you a great deal:

What sealing properly gets you

Comfort and energy. A sealed window stops the conditioned air leaking out, which is what the air conditioning has been fighting.

Quiet. Air paths are sound paths. Restoring gasket compression is often the cheapest acoustic improvement on an existing window. If you need more than that, acoustic inserts are the next step.

Less dust. The same gap that carries noise carries Mumbai’s road dust onto the sill.

Frame protection. Water trapped in a frame is what rots timber and corrodes steel. Sealing and drainage done properly is the cheapest form of frame repair — the kind you do before it is needed.

When sealing is not the answer

If the frame has moved out of square, no gasket will seal against it, because the gap varies along the length of the sash. If the frame has rotted or corroded through, sealant is covering a structural problem. In both cases the honest answer is repair or replacement, and we will tell you that rather than applying a cosmetic fix.

Most of this is checkable yourself in half an hour — see the pre-monsoon window checklist. Tell us where the water appears and when, and we can usually name the failing seal before we arrive.

Common questions

What are the three seals on a window and which one is failing?

The gasket (the rubber the sash compresses when it closes), the perimeter seal (between the frame and the wall), and the drainage path. Water on the sill points to drainage; water at the jambs or head points to the perimeter seal; draughts and noise with no water usually mean the gasket.

Why should drainage slots never be sealed?

Because a window frame is designed to let some water in and drain it back out. The weep holes at the sill are that escape route. Sealing them traps water inside the frame, where it soaks the reveal, corrodes hardware and rots timber — the opposite of what was intended.

Can I just use silicone from a hardware shop?

For a small gap in sound sealant, sometimes. The problem is that sealant applied over a failed joint, a wet surface, or a drainage slot makes things worse. And if the real fault is a hardened gasket, no amount of external sealant will fix it — the leak path is inside the window.

How long do window seals last in Mumbai?

Gaskets typically harden after several years of UV and heat, faster on west and south-west elevations. Exterior sealant also degrades under UV. Both are consumables rather than permanent parts, which is why they are on the annual [maintenance](/windows/service-and-repair/maintenance/) checklist.

Will sealing reduce noise as well as draughts?

Yes, measurably. Sound and air take the same path, so a window that leaks air leaks noise. Restoring a proper gasket compression is often the cheapest acoustic improvement available on an existing window.